Basic Info.
Energy Efficiency Grade
Three
Work Environment
Common Heat Pump
Heating Type
Multi-power Heat
Application
Villa Family, Sauna and Swimming Pool, Hotels, Factory Hospital, Student Apartments
Certification
CE, ISO9001, CB, RoHS
Product Description
R32 ERP A+++ 6KW/9.5KW/12KW/16KW EVI DC Inverter Air to Water Heat Pumps - Monoblock Type is a reliable solution for cold climates. These heat pumps can accommodate anyone's heating needs with their operating temperature range of -25°C to 45°C, 6KW/9.5W/12KW/16KW of heating power, 10.9KW of cooling power, and power supply ranges of 220V-240V or 380V-420V. This air to water heat pump operates more efficiently while having no impact on the environment thanks to the use of R32 refrigerant gas. With an ERP A+++ certification, a 5.56 COP, and a DC inverter that more effectively circulates the fluids, it has improved efficiency. Users can save money on their heating expenses thanks to these pros.
Model | | CGK015V3L | CGK025V3L | CGK030V3L | CGK040V3L | CGK-025V3L | CGK-030V3L | CGK-040V3L |
Power Supply / Refrigerant | V/Hz/Ph | 220-240/50/1 - R32 | 380-420/50/3 - R32 |
Max. Heating Capacity (1) | kW | 6 | 9.5 | 12 | 16 | 9.5 | 12 | 16 |
C.O.P (1) | W/W | 4.45 | 4.58 | 4.45 | 4.71 | 4.58 | 4.45 | 4.71 |
Heating Capacity Min./Max.(1) | kW | 2.76 | / | 6 | 4.37 | / | 9.5 | 5.52 | / | 12 | 7.36 | / | 16 | 4.37 | / | 9.5 | 5.52 | / | 12 | 7.36 | / | 16 |
Heating Power Input Min./Max.(1) | W | 496 | / | 1348 | 763 | / | 2074 | 992 | / | 2697 | 1250 | / | 3397 | 763 | / | 2074 | 992 | / | 2697 | 1250 | / | 3397 |
C.O.P Min./Max.(1) | W/W | 4.45 | / | 5.56 | 4.58 | / | 5.73 | 4.45 | / | 5.56 | 4.71 | / | 5.89 | 4.58 | / | 5.73 | 4.45 | / | 5.56 | 4.71 | / | 5.89 |
Max. Heating Capacity(2) | kW | 5.8 | 9.1 | 11.5 | 15.4 | 9.1 | 11.5 | 15.4 |
C.O.P (2) | W/W | 3.60 | 3.71 | 3.60 | 3.82 | 3.71 | 3.60 | 3.82 |
Heating Capacity Min./Max.(2) | kW | 2.65 | / | 5.76 | 4.20 | / | 9.12 | 5.30 | / | 11.52 | 7.07 | / | 15.36 | 4.20 | / | 9.12 | 5.30 | / | 11.52 | 7.07 | / | 15.36 |
Heating power input Min./Max.(2) | W | 627 | / | 1618 | 964 | / | 2489 | 1254 | / | 3236 | 1579 | / | 4076 | 964 | / | 2489 | 1254 | / | 3236 | 1579 | / | 4076 |
C.O.P Min./Max.(2) | W/W | 3.56 | / | 4.23 | 3.66 | / | 4.35 | 3.56 | / | 4.23 | 3.77 | / | 4.47 | 3.66 | / | 4.35 | 3.56 | / | 4.23 | 3.77 | / | 4.47 |
Max. Cooling Capacity(3) | kW | 5.5 | 8.7 | 10.9 | 14.6 | 8.7 | 10.9 | 14.6 |
E.E.R (3) | W/W | 3.50 | 3.60 | 3.50 | 3.70 | 3.60 | 3.50 | 3.70 |
Cooling Capacity Min./Max.(3) | kW | 2.52 | / | 5.47 | 3.99 | / | 8.66 | 5.03 | / | 10.94 | 6.71 | / | 14.59 | 3.99 | / | 8.66 | 5.03 | / | 10.94 | 6.71 | / | 14.59 |
Cooling Power Input Min./Max.(3) | W | 608 | / | 1852 | 935 | / | 2849 | 1215 | / | 3704 | 1531 | / | 4666 | 935 | / | 2849 | 1215 | / | 3704 | 1531 | / | 4666 |
E.E.R Min./Max.(3) | W/W | 2.95 | / | 4.14 | 3.04 | / | 4.26 | 2.95 | / | 4.14 | 3.13 | / | 4.39 | 3.04 | / | 4.26 | 2.95 | / | 4.14 | 3.13 | / | 4.39 |
Max. Cooling Capacity(4) | kW | 3.9 | 6.2 | 8.6 | 10.4 | 6.2 | 8.6 | 10.4 |
E.E.R(4) | W/W | 2.52 | 2.59 | 2.62 | 2.66 | 2.59 | 2.62 | 2.66 |
Cooling Capacity Min./Max.(4) | kW | 1.80 | / | 3.92 | 2.85 | / | 6.20 | 3.97 | / | 8.64 | 4.80 | / | 10.44 | 2.85 | / | 6.20 | 3.97 | / | 8.64 | 4.80 | / | 10.44 |
Cooling Power Input Min./Max.(4) | W | 494 | / | 1559 | 760 | / | 2399 | 1090 | / | 3440 | 1245 | / | 3929 | 760 | / | 2399 | 1090 | / | 3440 | 1245 | / | 3929 |
E.E.R Min./Max.(4) | W/W | 2.51 | / | 3.65 | 2.58 | / | 3.75 | 2.51 | / | 3.65 | 2.66 | / | 3.86 | 2.58 | / | 3.75 | 2.51 | / | 3.65 | 2.66 | / | 3.86 |
Rated Current | A | 6.5 | 9.9 | 12.9 | 16.3 | 4.4 | 5.7 | 7.2 |
Max Power Input | kW | 2.0 | 3.0 | 3.9 | 4.9 | 3.0 | 3.9 | 4.9 |
Max Current | A | 9.4 | 14.4 | 18.7 | 23.6 | 6.3 | 8.3 | 10.4 |
Fuse or circuitbreakerer | A | 16A | 20A | 25A | 32A | 13A | 13A | 16A |
Compressor | Type - Quantity/System | | Twin Rotary - 1 | Twin Rotary - 1 | Twin Rotary - 1 | Twin Rotary - 1 | Twin Rotary - 1 | Twin Rotary - 1 | Twin Rotary - 1 |
Fan | Quantity | | 1 | 1 | 1 | 1 | 1 | 1 | 1 |
Airflow | m3/h | 1500 | 2500 | 3000 | 3500 | 2500 | 3000 | 3500 |
Rated power | W | 60 | 80 | 100 | 120 | 80 | 100 | 120 |
Water Side Heat Exchanger | Type | | Plate Heat Exchanger | Plate Heat Exchanger | Plate Heat Exchanger | Plate Heat Exchanger | Plate Heat Exchanger | Plate Heat Exchanger | Plate Heat Exchanger |
Water Pressure Drop | kPa | 14 | 18 | 20 | 21 | 18 | 20 | 21 |
Piping Connection | Inch | G3/4" | G1" | G1" | G1" | G1" | G1" | G1" |
Allowable Water Flow | Min./Rated./Max. | L/S | 0.18 | 0.29 | 0.48 | 0.28 | 0.45 | 0.76 | 0.36 | 0.57 | 0.96 | 0.48 | 0.76 | 1.27 | 0.28 | 0.45 | 0.76 | 0.36 | 0.57 | 0.96 | 0.48 | 0.76 | 1.27 |
Noise Level | | dB(A) | 49 | 56 | 59 | 60 | 56 | 59 | 60 |
Net Dimension(L×D×H) | mm | 990*375*655 | 1110*475*810 | 1110*475*810 | 1110*475*960 | 1110*475*810 | 1110*475*810 | 1110*475*960 |
Packing Dimension(L×D×H) | | mm | 1070*405*800 | 1200*540*970 | 1200*540*970 | 1200*540*1120 | 1200*540*970 | 1220*540*970 | 1200*540*1120 |
Net Weight | Kg | 59 | 80 | 88 | 98 | 80 | 88 | 98 |
Gross Weight | | Kg | 80 | 108 | 116 | 126 | 108 | 116 | 126 |
Note: (1) Heating condition: water inlet/outlet temperature: 30ºC/35ºC, Ambient temperature: DB 7ºC/WB 6ºC; |
(2) Heating condition: water inlet/outlet temperature: 40ºC/45ºC, Ambient temperature: DB 7ºC/WB 6ºC; |
(3) Cooling condition: water inlet/outlet temperature: 23ºC/18ºC, Ambient temperature: DB35ºC/WB24ºC; |
(4) Cooling condition: water inlet/outlet temperature: 12ºC/7ºC, Ambient temperature: DB35ºC/WB24ºC; |
The new refrigerant gas R32 helps our DC inverter heat pumps operate more cleanly and effectively, which has less harmful effects on the atmosphere with lower carbon emissions and zero ozone depleting potential.
With maximum COP 5.95, our ERP A+++ R32 EVI DC inverter heat pumps charge and recirculate more efficiently than DC inverter heat pumps of other refrigerants. They consume less energy, and can therefore help families reduce energy bills.
The CAREL controller is able to record temperatures unaided using sensors that record the surrounding conditions. With the WIFI online monitoring, customers will enjoy contactless support from our customer service center no matter where they are. Our R32 EVI DC inverter heat pumps are also featured with more intelligent protections.
In addition to brushless DC inverter fans, SPRSUN R32 DC inverter heat pumps adopt reinforced sound reduction measures such as the dual shock absorption by Panasonic Compressor. The sound levels start as low as 42 dBA, making itself the quietest system in our DC inverter lineup.
The refrigerant R32 is considered to be environment friendly, but improper handling and storage might lead to potential safety issues. All of this can be avoid by using SPRSUN R32 DC inverter heat pumps, since they are designed with anti-explosion measures to guarantee the safety.
Q1 Are you a manufacturer?
A: Yes, we are a professional heat pump manufacturer since 1999, with experienced and improved R&D, production, sales and service supply.
Q2: What are your main products?
A: Our main products include dc inverter heat pumps, air source heat pump water heaters, swimming pool heat pumps, EVI heat pumps for cold areas and so on.
Q3: How to place an order?
A: Please send us an inquiry or contact us with online service; after receiving your inquiry, we will reply to you with our
catalogue, quotation and other information you need.
Q4: Do you provide OEM/ODM customized manufacturing service?
A: Yes, we warmly welcome your heat pump OEM/ODM opportunities. We can produce Europe standard heat pumps under your brand and according to your special needs.
Q5: Can I apply to become your heat pump distributor/reseller?
A: Yes, we are currently looking for more heat pump distributors/resellers across the globe, who can distribute our heat pump products in their local countries.
Address:
No. 6 Hongyuan Road, East Section of Economic and Technical Development Zone, Guangzhou, Guangdong, China
Business Type:
Manufacturer/Factory, Trading Company
Business Range:
Consumer Electronics, Industrial Equipment & Components, Manufacturing & Processing Machinery
Management System Certification:
ISO 14000, ISO 14001, ISO 9001, ANSI/ESD
Company Introduction:
Founded in 1999 as a professional heat pump manufacturer, Guangzhou SPRSUN new energy Technology Development Co., Ltd has been in heat pump business for about 15 years. It is built up to meet customers′ special energy saving needs with advanced technology support from Germany while ISO9001, ISO14001 have been obtained.
Our Products
With a strong R&D center and production line, we are specialized in producing and supplying air source heat pump, water/ground source heat pump, swimming pool heat pump, high temp. Heat pump, EVI heat pump for cold area and so on. All the products are developed and produced based on EN14511 standard that CE, CB, GS, CCC, ETL certificates and patents are obtained while for some, EN14511 test report are released by TUV.
Our Markets
Our products are welcome by lots of customers all over the world for its energy saving performance and good quality which keeps customers free from worries of the problem. Our main market is Germany, Britain, Sweden, Serbia, Turkey, the Czech Republic, Russia, Australia, South Africa and so on.
Our Service
With dedicated professional members in engineering team, production team, management team and marketing team, we are willing to cooperate with you from the very beginning to the end. Our service covers from project consultation, product design, sampling, production to quality control, logistics, shipping, technical support, after sales service and other important functions.
Over the years, excellent products based on leading technology and professional service have earned SPRSUN its reputation as the world′s leading heat pump manufacturing and supplying company. Let′s grow stronger and inspire the next together.